What is the situation that causes the high pressure of the water chiller beyond all normal categories?
As we all know, the water cooler is divided into air cooler box chiller and water cooler box chiller, different water cooler, of course the way to solve the problem is not the same.
If it is an air cooler box chiller, professional and technical personnel should check whether the installation working temperature exceeds 40℃, and if it exceeds it, they should dissipate heat immediately, because the refrigeration water output is too small, or the temperature is too high and the heat is not very good, and there will be high pressure alarm.
For the refrigeration water is too small, we should also remember to check whether the water inlet valve is opened to the larger part, prevent high pressure alarm and ensure that the chiller is in the natural environment of the gas circulation system.
Most of the reasons leading to the high pressure alarm of the water cooler box chiller are due to the cooling system. If the circulating water valve is not opened carefully, the actual operation is not carried out, so that the cooling circulating water cannot be circulated to the chiller. There is also a situation which may be due to the problem of the closed cooling tower. Try to check whether the closed cooling tower is not very good to appear.
After the above 2 problems are carefully carefully good, but also check whether there are stains in the water into the respiratory system deposition, it is best to replace the water again, but also to clean up the machinery and equipment, cleaning on time will make industrial water cooler machine equipment efficient operation, so cleaning on time also seems crucial.